Beverage-Air Error Codes
What Beverage-Air fault codes and alarms mean, and what a technician checks for each one. Need it fixed? We repair Beverage-Air equipment across the Charlotte area.
Eliwell / Danfoss controllers (BZ, MMR and others)
| Code | Meaning | What to check |
|---|---|---|
| dEF | Defrosting (normal) | No action. |
| Hi | Cabinet / air temperature above high alarm limit | Confirm doors/drawers closed; clears automatically. |
| Lo | Air temperature below low alarm limit | |
| Con | Condenser temperature too high or too low | Clean condenser, check condenser fan. |
| dor / dOr | Door open too long | Close door; if persists, service. |
| uHi / uLi | Line voltage above / below limit | Check supply voltage. |
| LEA | Compressor running continuously too long | Check doors closed; else service. |
| E01–E04 | Sensor S1–S4 unplugged, shorted or failed | Call for service. |