Commercial Equipment Error Code Library
431 fault codes for commercial ice machines, refrigeration controllers, walk-ins, ovens, fryers, dishwashers, washers and dryers. Find your brand, then your code. Codes can differ between control-board generations — if you are not sure, call us with the model number.
Manitowoc29 codes · Ice machineScotsman27 codes · Ice machineHoshizaki6 codes · Ice machineIce-O-Matic7 codes · Ice machineDixell13 codes · Reach-in refrigerator / freezer / prep tableDanfoss6 codes · Reach-in refrigerator / freezer / prep tableDelfield14 codes · Reach-in refrigerator / freezer / prep tableContinental Refrigerator3 codes · Reach-in refrigerator / freezer / prep tableTrue7 codes · Reach-in refrigerator / freezer / prep tableHeatcraft / Bohn / Larkin12 codes · Walk-in cooler / freezerDexter21 codes · Commercial washerContinental Girbau21 codes · Commercial washerSpeed Queen / Huebsch / UniMac18 codes · Commercial dryer, Commercial washerBeverage-Air8 codes · Reach-in refrigerator / freezer / prep tableTraulsen3 codes · Reach-in refrigerator / freezer / prep tableTurbo Air3 codes · Reach-in refrigerator / freezer / prep tableFollett4 codes · Ice machineKE2 Therm11 codes · Walk-in cooler / freezerCarel12 codes · Reach-in refrigerator / freezer / prep tableKolpak7 codes · Walk-in cooler / freezerMaytag Commercial44 codes · Commercial washerADC – American Dryer Corp.22 codes · Commercial dryerElectrolux Professional / Wascomat30 codes · Commercial dryer, Commercial washerMilnor9 codes · Commercial washerHobart20 codes · Commercial dishwasherFrymaster24 codes · Commercial fryerPitco8 codes · Commercial fryerHenny Penny8 codes · Commercial fryerRational17 codes · Commercial oven / combiTurboChef11 codes · Commercial oven / combiBlodgett6 codes · Commercial oven / combi
| Brand | Code | Meaning |
|---|---|---|
| Manitowoc | E01 | Long Freeze |
| Manitowoc | E02 | Long Harvest |
| Manitowoc | E03 | Power Loss |
| Manitowoc | E04 | Hi Cnd Temp / Wtr Cnd Fault |
| Manitowoc | E05 | HPC Fault |
| Manitowoc | E07 | Starving TXV |
| Manitowoc | E08 | TXV Fault |
| Manitowoc | E09 | Flood Evap 1 |
| Manitowoc | E10 | Flood Evap 2 |
| Manitowoc | E11 | Refrig Fault |
| Manitowoc | E12 | Curtain Fault |
| Manitowoc | E15 | Low Liq Temp |
| Manitowoc | E16 | Rmt Cnd Temp |
| Manitowoc | E19 | ITP Fault |
| Manitowoc | E20 | WTR Fault |
| Manitowoc | E21 | T1 Fault |
| Manitowoc | E22 | T2 Fault |
| Manitowoc | E23 | T3 Fault |
| Manitowoc | E24 | T4 Fault |
| Manitowoc | E25 | Bin Prb Fault (low) |
| Manitowoc | E26 | Bin Prb Fault (medium) |
| Manitowoc | E27 | Bin Prb Fault (high) |
| Manitowoc | E28 | AuCS |
| Manitowoc | E29 | USB COMM |
| Manitowoc | E30 | USB DNLD |
| Manitowoc | E31 | Safe Mode |
| Manitowoc | E32 | RS485 COMM |
| Manitowoc | E33 | KEYBOARD |
| Manitowoc | E34 | DISPLAY |
| Scotsman | 1 | Long freeze time, shutting down (flashing = retrying) |
| Scotsman | 2 | Long harvest time, shutting down (flashing = retrying) |
| Scotsman | 3 | Water filling slowly |
| Scotsman | 4 | High discharge temperature |
| Scotsman | 5 | Failed sump temperature sensor |
| Scotsman | 7 | Failed discharge temperature sensor |
| Scotsman | 8 | Short freeze cycle, retrying (flashing = thin ice) |
| Scotsman | F / F flashing | Freeze cycle / pending freeze (status, not fault) |
| Scotsman | H | Harvest cycle (status) |
| Scotsman | b | Bin full (status) |
| Scotsman | C | Clean cycle (status) |
| Scotsman | L | Board locked |
| Scotsman | d | Test mode |
| Scotsman | O | Off |
| Scotsman | E | Failed self test |
| Scotsman | 1 | No ice sensed, shutting down (flashing = retrying) |
| Scotsman | 2 | Auger motor high load, shutting down (flashing = retrying) |
| Scotsman | 3 | No water in reservoir |
| Scotsman | 4 | Refrigeration pressure too high or low |
| Scotsman | E | Self test failed |
| Scotsman | Water light on | Water pump defective or water level not sensed/too low |
| Scotsman | Water light blinks 2x | Water inlet valve faulty |
| Scotsman | Refrigeration light on | Low discharge / long freeze / hot gas valve faulty / exceeds max freeze time |
| Scotsman | Refrigeration blinks 1x | Harvest error (cubes sensed) |
| Scotsman | Refrigeration blinks 2x | Harvest error (no cubes sensed) |
| Scotsman | Refrigeration blinks 3x | High discharge temperature |
| Scotsman | Refrigeration + water lights (running) | Temperature sensors out of range |
| Hoshizaki | 1 beep | Evaporator overheated during harvest (high temp safety) |
| Hoshizaki | 2 beeps | Two consecutive long harvests (20-min harvest backup) |
| Hoshizaki | 3 beeps | Two consecutive long freeze cycles |
| Hoshizaki | 4 / 5 beeps (older mech. bin control) | Bin control K-4 connector short (4) / open (5) — KM-280/500/630/900 |
| Hoshizaki | 6 beeps | Low voltage |
| Hoshizaki | 7 beeps | High voltage |
| Ice-O-Matic | Error 1 | Max freeze (~1 hr) then short harvest |
| Ice-O-Matic | Error 2 | Max harvest — ice did not drop within 7 min |
| Ice-O-Matic | Error 3 | Hour-long freeze + 7-min harvest |
| Ice-O-Matic | Error 4 | Thermistor failure |
| Ice-O-Matic | Error 5 | Max fill — fill took 5+ min |
| Ice-O-Matic | Error 6 | Max purge (2 min purge, off 10 min, retry) |
| Ice-O-Matic | Error 7 | Float switch did not open within 15 s of pump start (3 tries) |
| Dixell | P1 | Thermostat (room) probe failure |
| Dixell | P2 | Evaporator probe failure |
| Dixell | P3 | Third / auxiliary probe failure |
| Dixell | P4 | Fourth probe failure |
| Dixell | HA | Maximum (high) temperature alarm |
| Dixell | LA | Minimum (low) temperature alarm |
| Dixell | HA2 / LA2 | Condenser high / low temperature |
| Dixell | dA | Door switch / door open alarm |
| Dixell | EA / EAL | External alarm |
| Dixell | CA / BAL | Serious external alarm — outputs off |
| Dixell | PAL | Pressure switch alarm |
| Dixell | EE | Data / memory (EEPROM) failure |
| Dixell | rtc | Real-time clock alarm |
| Danfoss | A01 | High temperature alarm |
| Danfoss | A02 | Low temperature alarm |
| Danfoss | A99 | High voltage alarm |
| Danfoss | E27 | Defrost sensor (S5) error |
| Danfoss | E29 | Air sensor (Sair) error |
| Danfoss | E30 | Condenser sensor (Sc) error |
| Delfield | E-1 | Box temperature sensor open/shorted or control faulty |
| Delfield | E-2 | Coil temperature sensor open/shorted or control defective |
| Delfield | E-6 | Defective potentiometer in unit control |
| Delfield | E-13 | Loose display-to-controller cable, or faulty display/control |
| Delfield | Er 1 / Er 5 | Software or hardware failure |
| Delfield | Er 2 | Faulty display module cable |
| Delfield | Er 3 | Temperature sensor open or shorted |
| Delfield | Er 4 | Evaporator sensor open or shorted |
| Delfield | Er 6 | Below low alarm setpoint |
| Delfield | Er 7 | Above high alarm setpoint |
| Delfield | E01 | Defective air sensor |
| Delfield | E02 | Faulty coil sensor |
| Delfield | Lo / Hi | Temperature below / above setpoint |
| Delfield | LEA | Cooling continuously over 24 h |
| Continental Refrigerator | E0 | Regulation probe — loose wire/connection |
| Continental Refrigerator | E1 | Evaporator probe faulty |
| Continental Refrigerator | E2 | Ambient probe / faulty control |
| True | E1 | Thermostat (cabinet) probe failure |
| True | E2 | Evaporator probe malfunction |
| True | E3 | Auxiliary / display probe |
| True | tHi / HA | High temperature alarm |
| True | tLo / LA | Low temperature alarm |
| True | do | Door open alert |
| True | P1 | Cabinet probe failure on Dixell-equipped units (see Dixell) |
| Heatcraft / Bohn / Larkin | A1 | High box temperature |
| Heatcraft / Bohn / Larkin | A2 | Low box temperature |
| Heatcraft / Bohn / Larkin | A3 | System start-up failure |
| Heatcraft / Bohn / Larkin | A4 | Input fault |
| Heatcraft / Bohn / Larkin | E1 | Room temperature sensor shorted/open/missing |
| Heatcraft / Bohn / Larkin | E2 | Defrost temperature sensor shorted/open/missing |
| Heatcraft / Bohn / Larkin | E3 | Suction temperature sensor shorted/open/missing |
| Heatcraft / Bohn / Larkin | E4 | Suction pressure transducer shorted/open/missing |
| Heatcraft / Bohn / Larkin | E5 | Outdoor temperature sensor shorted/open/missing |
| Heatcraft / Bohn / Larkin | E6 | Low superheat |
| Heatcraft / Bohn / Larkin | E7 | Compressor shut down (HP/LP/oil switch open) |
| Heatcraft / Bohn / Larkin | E9 | Multi-in / multi-out wiring error |
| Dexter | F1 | Door failed to close/lock after 3 tries |
| Dexter | F2 | Tub didn't fill within 7 min |
| Dexter | F3 | Controller memory error |
| Dexter | F4 | Controller communication error |
| Dexter | F5 | Pressure switch error (OPL) |
| Dexter | F6 | Wrong washer size for drive type |
| Dexter | F7 | Wrong size drive installed |
| Dexter | F8 | Tub didn't empty within 7 min |
| Dexter | F9 | Tub didn't reach spin speed within 200 s |
| Dexter | F10 | Tub didn't stop within 150 s after spin |
| Dexter | F11 | Drive size setting changed |
| Dexter | F12 | Controller internal error |
| Dexter | F13 | Controller can't communicate with drive |
| Dexter | F14 | Over-current on drive or motor |
| Dexter | F15 | Over-voltage on drive or motor |
| Dexter | F16 | Drive overheating |
| Dexter | F17 | Overload of drive or motor |
| Dexter | F18 | Ground fault to drive |
| Dexter | F19 | Low voltage to drive |
| Dexter | F20 | Internal drive error |
| Dexter | F21 | Data error between controller and drive |
| Continental Girbau | ALn/VAR 0 | Microprocessor-to-inverter comms failure |
| Continental Girbau | ALn/VAR 1 | Inverter disconnected |
| Continental Girbau | ALn/VAR 2 | Inverter detects comm failure |
| Continental Girbau | ALn/VAR 3 | Inverter overcurrent |
| Continental Girbau | ALn/VAR 4 | Motor thermal cutout (klixon) open |
| Continental Girbau | ALn/VAR 5 | DC bus overvoltage |
| Continental Girbau | ALn/VAR 6 | Inverter overheating |
| Continental Girbau | ALn/VAR 7 | General inverter failure |
| Continental Girbau | ALn/VAR 8 | Unidentified inverter / unbalance control failure |
| Continental Girbau | ALn/VAR 9 | Model and inverter configuration mismatch |
| Continental Girbau | ALn/A | Faulty water supply — fill level not reached |
| Continental Girbau | ALn/E | Blocked drain |
| Continental Girbau | ALn/L | Water present when tub should be empty |
| Continental Girbau | ALn/SL | Persistent overfill |
| Continental Girbau | ALn/HOT | Cycle stopped with hot bath |
| Continental Girbau | ALn/C | Steam heat fault |
| Continental Girbau | ALn/Prob | Faulty temperature sensor |
| Continental Girbau | ALn/bAL | Unbalance detected |
| Continental Girbau | ALn door | Door fails to lock |
| Continental Girbau | Err/000 | Machine ID error |
| Continental Girbau | EnEr | Emergency stop open |
| Speed Queen / Huebsch / UniMac | door | Door open |
| Speed Queen / Huebsch / UniMac | E:0d | Pressure switch error |
| Speed Queen / Huebsch / UniMac | E:Pr | Pressure switch sequence error |
| Speed Queen / Huebsch / UniMac | E:FL | Fill error (30 min) |
| Speed Queen / Huebsch / UniMac | E:dr | Drain error |
| Speed Queen / Huebsch / UniMac | E:dF | Drive failure |
| Speed Queen / Huebsch / UniMac | E:dL | Door lock error |
| Speed Queen / Huebsch / UniMac | E:dO | Door opened during cycle |
| Speed Queen / Huebsch / UniMac | E:HT | Heater error |
| Speed Queen / Huebsch / UniMac | E:SP | SPI communication error |
| Speed Queen / Huebsch / UniMac | E:Ub | Unbalanced load |
| Speed Queen / Huebsch / UniMac | Alrm | Break-in alarm |
| Speed Queen / Huebsch / UniMac | E:OP / OP | Open temperature sensor |
| Speed Queen / Huebsch / UniMac | E:SH / SH | Shorted temperature sensor |
| Speed Queen / Huebsch / UniMac | E:07 / E:08 | Inoperative control |
| Speed Queen / Huebsch / UniMac | EI:07 / EI:08 | Error writing RTC / EEPROM |
| Speed Queen / Huebsch / UniMac | Err | Coin error |
| Speed Queen / Huebsch / UniMac | EC:xx | Smart-card / card reader errors |
| Beverage-Air | dEF | Defrosting (normal) |
| Beverage-Air | Hi | Cabinet / air temperature above high alarm limit |
| Beverage-Air | Lo | Air temperature below low alarm limit |
| Beverage-Air | Con | Condenser temperature too high or too low |
| Beverage-Air | dor / dOr | Door open too long |
| Beverage-Air | uHi / uLi | Line voltage above / below limit |
| Beverage-Air | LEA | Compressor running continuously too long |
| Beverage-Air | E01–E04 | Sensor S1–S4 unplugged, shorted or failed |
| Traulsen | CLN-FIL | Condensing temperature reached 140°F or higher |
| Traulsen | dEF | Defrost in progress (normal); ends at 45°F coil or 25/30-min backup |
| Traulsen | AL | Alarm submenu — alarm codes not published; call Traulsen 800-825-8220 |
| Turbo Air | Alarm light | Turbo Air manuals do not publish numeric codes — alarm light only; call Turbo Air support or check the unit's controller label |
| Turbo Air | Door Open light | Door is open |
| Turbo Air | Defrost light | Defrost active (normal) |
| Follett | HI AMPS | Auger gearmotor over current limit (soft error) |
| Follett | LO WATER | Water not detected at low sensor within 10 s (soft) |
| Follett | HI PRESSURE | Refrigeration pressure above 425 psi (soft) |
| Follett | DRAIN CLOG | Water near top of drain pan — drain not flowing (hard) |
| KE2 Therm | AtSA | Air temperature sensor alarm |
| KE2 Therm | CLSA | Coil temperature sensor alarm |
| KE2 Therm | HtA | High temperature alarm |
| KE2 Therm | LtA | Low temperature alarm |
| KE2 Therm | PF | Power failure |
| KE2 Therm | SSA / OSA | Shorted / open sensor alarm (KE2 Temp) |
| KE2 Therm | HSH | High superheat alarm |
| KE2 Therm | HCA | High condensing temperature (high-side control) |
| KE2 Therm | HdA | High discharge temperature (high-side control) |
| KE2 Therm | CHA / LHA | Humidity board comm lost / low humidity |
| KE2 Therm | CLA | Menu item to clear alarms (hold until red LED blinks) |
| Carel | rE | Virtual control probe fault |
| Carel | E0 | Room probe S1 fault |
| Carel | E1 | Defrost probe S2 fault |
| Carel | E2 / E3 / E4 | Probe S3–S5 fault |
| Carel | LO | Low temperature alarm |
| Carel | HI | High temperature alarm |
| Carel | AFr | Antifreeze alarm (manual reset) |
| Carel | IA | Immediate alarm from external contact |
| Carel | CHT / cht | High condenser temperature alarm / pre-alarm |
| Carel | dor | Door open too long |
| Carel | Etc | Real-time clock fault |
| Carel | EE / EF | EEPROM error (parameters) |
| Kolpak | DOOR OPEN ALARM | Door open longer than door alarm delay |
| Kolpak | DOOR TEMP SENSOR ALARM | Temp 1 input shorted or open |
| Kolpak | ROOMTEMP2/3 SENSOR ALARM | Temp 2/3 input shorted or open |
| Kolpak | HIGH / LOW MONITOR TEMP2/3 ALARM | Temperature above/below offset longer than delay |
| Kolpak | HIGH / LOW DOOR TEMP ALARM | Door temp above/below offset (door heater issue) |
| Kolpak | EXTERNAL ALARM 1-3 | External alarm input active |
| Kolpak | 888.8 reading | Sensor failure |
| Maytag Commercial | d1 | Water level circuit failure on control |
| Maytag Commercial | d3 | Water temp sensor error |
| Maytag Commercial | d4 | Lid switch circuit failure |
| Maytag Commercial | d5 | Blocked Coin 1 / circuit error |
| Maytag Commercial | d7 | Slow fill |
| Maytag Commercial | d8 | Slow drain |
| Maytag Commercial | d9 | Low voltage |
| Maytag Commercial | d12 | Motor sense circuit failure |
| Maytag Commercial | d13 | Blocked Coin 2 / circuit error |
| Maytag Commercial | d16 | No communication from debit card reader |
| Maytag Commercial | F01 | Main control fault |
| Maytag Commercial | F03 | Pressure sensor fault |
| Maytag Commercial | F07 | Shifter/actuator fault |
| Maytag Commercial | F11 | Motor control fault |
| Maytag Commercial | F20 | Long fill |
| Maytag Commercial | F21 | Long drain |
| Maytag Commercial | F22 | Lid lock fault |
| Maytag Commercial | F24 | Temperature sensor fault |
| Maytag Commercial | F25 | Basket speed sensor fault |
| Maytag Commercial | F26 | Lid switch fault |
| Maytag Commercial | F27 | Overflow |
| Maytag Commercial | F29 | Lid unlock fault |
| Maytag Commercial | F32 | No fill |
| Maytag Commercial | F70 / F71 | CCU to UI communication fault |
| Maytag Commercial | F73 / F74 | UI EEPROM fault |
| Maytag Commercial | F77 | Off-balance load |
| Maytag Commercial | F01 | CCU error |
| Maytag Commercial | F03 / F04 | Accelerometer failure (MHN33) |
| Maytag Commercial | F11 | Motor control unit failure |
| Maytag Commercial | F20 | Slow fill |
| Maytag Commercial | F21 | Slow drain |
| Maytag Commercial | F22 | Door lock error |
| Maytag Commercial | F24 | Temperature sensor |
| Maytag Commercial | F25 | Tachometer error |
| Maytag Commercial | F26 | Door switch error |
| Maytag Commercial | F27 | Overflow |
| Maytag Commercial | F28 | CCU–MCU communication error |
| Maytag Commercial | F29 | Door unlock error |
| Maytag Commercial | F30 | Dispenser error (MAH22) |
| Maytag Commercial | F31 | Motor overheating |
| Maytag Commercial | F33 | Pump sensed disconnected |
| Maytag Commercial | F34 | Load detected during clean cycle |
| Maytag Commercial | Help 0F / 33 | Oversuds not resolved |
| Maytag Commercial | Help 32 | More than 6 unbalance retries — spin aborted |
| ADC – American Dryer Corp. | MAIN DOOR OPENED | Main door open |
| ADC – American Dryer Corp. | LINT ACCESS OPEN | Lint drawer open |
| ADC – American Dryer Corp. | EXHAUST HIGH TEMP FAULT | Tumbler temperature above 220°F |
| ADC – American Dryer Corp. | EXHAUST HIGH LIMIT FAULT | Exhaust temperature disk opened |
| ADC – American Dryer Corp. | SAIL SWITCH CLOSED / OPEN FAULT | Airflow (sail) switch in wrong state |
| ADC – American Dryer Corp. | BURNER HIGH LIMIT FAULT | Burner temperature disk opened |
| ADC – American Dryer Corp. | BURNER IGNITION CONTROL FAULT | No gas valve signal from DSI module during ignition trial |
| ADC – American Dryer Corp. | IGNITION FAULT | No flame after ignition trial |
| ADC – American Dryer Corp. | FLAME FAULT | Flame lost after ignition (5 retries) |
| ADC – American Dryer Corp. | ROTATION FAULT | Tumbler not rotating |
| ADC – American Dryer Corp. | OPEN EXHAUST TEMPERATURE PROBE | Exhaust probe open/shorted |
| ADC – American Dryer Corp. | OPEN S.A.F.E. SYSTEM PROBE FAULT | Fire-suppression probe open/shorted |
| ADC – American Dryer Corp. | LOW VOLTAGE FAULT | Supply voltage too low |
| ADC – American Dryer Corp. | BURNER PURGE FAULT | Gas valve signal present during prepurge |
| ADC – American Dryer Corp. | MODEL ERROR | Wrong model selected in control |
| ADC – American Dryer Corp. | EE PROM FAULT ### | Memory error at location ### |
| ADC – American Dryer Corp. | LINT dOOR / MAIN dOOR | Lint drawer / main door opened during run |
| ADC – American Dryer Corp. | dRUM Safety FAIL | Tumbler hi-limit opened while heating |
| ADC – American Dryer Corp. | SAIL SWITCH FAIL | Sail switch closed before start |
| ADC – American Dryer Corp. | NO AIRFLOW | Sail switch opened mid-cycle |
| ADC – American Dryer Corp. | bURNER SAFETY FAIL | Burner hi-limit opened |
| ADC – American Dryer Corp. | bURNER CONTROL FAIL | Gas valve signal not received in time |
| Electrolux Professional / Wascomat | 10:1 | CPU tacho internal error |
| Electrolux Professional / Wascomat | 10:11 | Real-time clock out of order |
| Electrolux Professional / Wascomat | 10:15 / 10:16 | Machine stop / emergency stop input active |
| Electrolux Professional / Wascomat | 11:1 | No water — fill level not reached in ~10 min |
| Electrolux Professional / Wascomat | 11:2 | Door open during program |
| Electrolux Professional / Wascomat | 11:3 | Door lock fail |
| Electrolux Professional / Wascomat | 11:4 / 11:5 | Water temp sensor low (open) / high (short) |
| Electrolux Professional / Wascomat | 11:6 | Water in machine at program end |
| Electrolux Professional / Wascomat | 11:8 | No heating |
| Electrolux Professional / Wascomat | 11:9 | Drum overfilled |
| Electrolux Professional / Wascomat | 11:10 | Max drain time exceeded |
| Electrolux Professional / Wascomat | 11:12 | No level sensor |
| Electrolux Professional / Wascomat | 11:16 | Heating timeout |
| Electrolux Professional / Wascomat | 13:7 | Drum not rotating (barrier) |
| Electrolux Professional / Wascomat | 13:15 | Compressed air missing (barrier) |
| Electrolux Professional / Wascomat | 20:1 | Drum motor overheat |
| Electrolux Professional / Wascomat | 20:2 / 20:3 | No / lost motor communication |
| Electrolux Professional / Wascomat | 21:1 / 21:2 | MCU heatsink / motor too hot |
| Electrolux Professional / Wascomat | 21:5 | Motor short circuit |
| Electrolux Professional / Wascomat | 21:7 / 21:8 | Low / high DC voltage |
| Electrolux Professional / Wascomat | 21:13 | Unbalance switch active at start |
| Electrolux Professional / Wascomat | 21:15 | Motor not following (no tacho feedback) |
| Electrolux Professional / Wascomat | 22:1 / 22:2 / 22:3 / 22:4 | Drive overvoltage / undervoltage / phase failure / overcurrent |
| Electrolux Professional / Wascomat | 22:6 / 22:8 | Drive internal / power module overheat |
| Electrolux Professional / Wascomat | 12:1 / 12:2 | Overheat thermostat inlet / outlet air |
| Electrolux Professional / Wascomat | 12:3–12:6 | Inlet/outlet air sensor open or shorted |
| Electrolux Professional / Wascomat | 12:11 / 12:12 / 12:13 | Drying error — stop value not reached within ~90 min |
| Electrolux Professional / Wascomat | 12:14 | Gas error — no flame |
| Electrolux Professional / Wascomat | 12:15 | No vacuum (airflow) |
| Electrolux Professional / Wascomat | 12:17 | Airflow obstructed — clean filter |
| Milnor | E0 | Door-closed signal lost after latch locked |
| Milnor | E1 | Door latch lock not confirmed in 5 s |
| Milnor | E2 | Coin acceptor pulses out of spec |
| Milnor | E3 | Level switch 'made' before wash |
| Milnor | E4 | Water level not reached in 10 min |
| Milnor | E5 | Water still present 40 s into drain |
| Milnor | E6 | Inverter fault |
| Milnor | E7 x | Input stuck at power-up (attendant switch, coin, level, vibration, select/start) |
| Milnor | E9 H | Door latch handle not fully closed at start |
| Hobart | E0, E2, E3, E4 | Not filling or not filling high enough — unit won't run |
| Hobart | E5 | Not draining properly |
| Hobart | E6 | Needs service |
| Hobart | CL / Pr | Filling too high or leaking from door |
| Hobart | P1, P2, P3 (wrench) | Needs service |
| Hobart | WASH ARM ALERT | Wash arm obstructed or clogged |
| Hobart | LOW RINSE TEMP | Low rinse temperature on consecutive cycles |
| Hobart | WASH / BOOSTER / RINSE TEMP SENSOR | Probe out of range |
| Hobart | FILL ERROR | Timed out before filling |
| Hobart | DRAIN ERROR | Drain problem — unit powers down |
| Hobart | SUMP / BOOSTER LEVEL SENSOR | Pressure switch out of range |
| Hobart | Clear Conveyor Jam | Rack jammed |
| Hobart | Probe Err – TANK | Lower float issue in tank |
| Hobart | Probe Error – FnlRns | Final rinse probe issue |
| Hobart | 01, 02 | Boiler temperature sensor |
| Hobart | 05, 06 | Tank temperature sensor high/low |
| Hobart | 07–10 | Pressure sensor high/low |
| Hobart | 13 | Tank filling pressure sensor monitor |
| Hobart | 14 | Wash tank draining during pump-out |
| Hobart | 17, 18, 31 | Filling monitoring — check water supply |
| Frymaster | E01 / E02 | REMOVE DISCARD right/left — setpoint differs from vat temp |
| Frymaster | E03 | Temperature probe failure |
| Frymaster | E04 | HI 2 BAD — high-limit reading out of range |
| Frymaster | E05 | HOT HI 1 — high limit above 410°F |
| Frymaster | E06 | HEATING FAILURE — controller, interface board, contactor, gas valve, open high limit |
| Frymaster | E07 / E08 | MIB software error |
| Frymaster | E09 | Pump not filling — dirty filter pad or pump |
| Frymaster | E10 / E11 | Drain valve not open / not closed |
| Frymaster | E12 / E13 | Return valve not open / not closed |
| Frymaster | E14 | AIF board error |
| Frymaster | E15 | MIB board error |
| Frymaster | E16 / E17 | AIF / ATO probe out of range |
| Frymaster | E19 | M3000 CAN TX full — lost communication |
| Frymaster | E20 | Invalid code location (SD card removed) |
| Frymaster | E21 | Change filter pad / procedure error |
| Frymaster | E22 | Oil in pan error |
| Frymaster | E23 | Clogged drain (gas) |
| Frymaster | E24 | AIF OIB failed (gas) |
| Frymaster | E25 / E26 | Recovery fault (recovery time exceeded) |
| Frymaster | E27 / E28 | Low / high temp alarm |
| Frymaster | PROB | Failed temperature probe or controller |
| Frymaster | HOT | Frypot above 410°F — turn off |
| Frymaster | HELP | Heating problem |
| Frymaster | CALL TECH | Memory chip failure |
| Pitco | Heat feedback flashes 7x | Drain valve detected open — heat cut |
| Pitco | Heat feedback flashes 3x | Thermal probe open or shorted |
| Pitco | Drn / DRAINING TURN OFF | Drain detected open |
| Pitco | Prob / PROBE OPEN | Probe fault |
| Pitco | Hi / HIGH TMP | Oil too hot or probe misreading |
| Pitco | Ignition Failure / HEAT FAILURE | Ignition lockout / high limit tripped / weak pilot |
| Pitco | SYSTEM FAILURE | Possibly shorted probe |
| Pitco | LoC | Program mode locked |
| Henny Penny | E-4 | Control board overheating (CPU TOO HOT) |
| Henny Penny | E-5 | Oil/shortening overheating |
| Henny Penny | E-6 | Temperature probe error |
| Henny Penny | E-10 | High limit tripped |
| Henny Penny | E-15 | Drain open while fryer on |
| Henny Penny | E-20 | Gas ignition system error (A–D sub-codes) |
| Henny Penny | E-41 | Lost programming |
| Henny Penny | E-46 | EEPROM write error |
| Rational | Service 10 | SC pump high water level |
| Rational | Service 11 / 12 | CDS sensor too many pulses / no signal |
| Rational | Service 13 / 14 | Steam generator not refilling / level electrode not detecting water |
| Rational | Service 17–19 | SD card not initialized / defective / missing |
| Rational | Service 20.x | Defective thermocouple (cabinet, quench, humidity, steam gen) |
| Rational | Service 23 / 24 | SSR steam / hot air short circuit |
| Rational | Service 25 | Improper water flow during CleanJet |
| Rational | Service 26 / 27 | Drain valve closed / won't close |
| Rational | Service 28 | Steam generator above 180°C |
| Rational | Service 29 | PCB above 85°C |
| Rational | Service 30 | Emergency humidity control |
| Rational | Service 31.x | Faulty core probe |
| Rational | Service 32 / 33 | Ignition box fault (gas) |
| Rational | Service 34.x | Bus signal problem (fan motor / ignition) |
| Rational | Service 36 / 37 | Differential pressure sensor |
| Rational | Service 40–44 | Care pump / solenoids / CleanJet+Care faults |
| Rational | Service 100 / 120 | SC pump or Care pump / level electrode |
| TurboChef | F1 | Blower running status bad |
| TurboChef | F2 | Cook temperature low |
| TurboChef | F3 | Magnetron current low |
| TurboChef | F4 | Door monitor defective (i3/i5) / E-stop pressed (conveyor) |
| TurboChef | F5 | Magnetron / cook cavity over temperature |
| TurboChef | F6 | Electrical compartment temperature high |
| TurboChef | F7 | RTD open (shows 999°) |
| TurboChef | F8 | Heat low / high limit tripped (conveyor) |
| TurboChef | F9 | Cook cavity temp high / belt run failure (conveyor) |
| TurboChef | F10 | UI–I/O board communication failure |
| TurboChef | F12 | Firmware reboot |
| Blodgett | Cavity Probe Error | Cavity probe below 32°F or above 575°F |
| Blodgett | Cavity High Temp Error | Cavity above 565°F or 150°F over setpoint |
| Blodgett | Cooling Fan / Quench Probe Error | Probe out of range |
| Blodgett | Fan Error | Fan drive @speed signal missing 15 s |
| Blodgett | Com Error | Lost COM signal from relay board |
| Blodgett | High Temp Error | Manual-reset high limit tripped (>671°F) |