Call (980) 478-8030

Preventive Maintenance Plans

Scheduled maintenance prevents most emergency breakdowns, keeps you inspection-ready and extends equipment life.

Basic

2 visits / year

  • Coil cleaning, filters, gaskets, drains
  • Temperature log & report
  • 10% off repairs

Standard

4 visits / year

  • Everything in Basic
  • Priority scheduling
  • Diagnostic fee waived
  • 15% off repairs

Premium

Monthly or bi-monthly

  • Ice machine sanitizing included
  • Fastest emergency response
  • 20% off repairs

Recommended maintenance schedule

Manufacturers' manuals require regular cleaning; skipped maintenance is the #1 cause of breakdowns (and can affect warranty).

Ice machines

Interval Task
Daily Check ice quality and production; keep scoop out of the bin
Monthly Clean air-cooled condenser (Follett manuals call for monthly condenser cleaning)
Every 6 months (minimum) Full clean, descale and sanitize; replace water filter; check water flow, ice thickness, bin control
Every 6–12 months Inspect evaporator, water pump, distribution tube, float/probes, drain lines; check refrigerant performance
Hard water, bakeries (yeast) and bars may need cleaning every 3 months.

Reach-in refrigerators, freezers & prep tables

Interval Task
Daily Log temperatures; keep doors closed; don't overload air vents
Weekly Clean door gaskets; wipe prep rail pans; check lid closes fully
Monthly Clean condenser coil / filter (kitchens with grease: monthly; others quarterly)
Quarterly Check door gaskets/hinges, drain lines and pans, evaporator fan, defrost operation, probe accuracy
Yearly Full electrical check, amp draw, refrigerant performance

Walk-in coolers & freezers

Interval Task
Daily Temperature log; keep door clear; check for ice on floor/ceiling
Monthly Inspect door gasket, sweep, door closer, heater wire (freezers)
Quarterly Clean evaporator coil and drain pan; check drain line heater (freezers); clean condensing unit coil; check fan motors
Semi-annual Defrost timer/controller settings, superheat/subcool, pressures, electrical connections, contactor

Bar / bottle coolers & merchandisers

Monthly: clean condenser (bar lint & dust). Quarterly: gaskets, fans, door heaters, lights.

Commercial dishwashers

Interval Task
Daily Drain and clean tank, scrap screens, wash and rinse arms; check chemical levels
Weekly Check rinse temperature / sanitizer level; inspect curtains (conveyors)
Monthly (or per water hardness) Delime machine and booster
Quarterly Inspect pumps, seals, gaskets, heating elements, fill and drain valves, chemical pumps

Fryers

Interval Task
Daily Filter oil; clean crumbs; check oil level
Weekly Boil-out the frypot; inspect drain valve
Monthly Clean flue/burners (gas); check filter pump and pads
Quarterly / semi-annual Calibrate thermostat/probe; test high limit; check gas pressure and ignition; inspect elements (electric)

Ovens & combi ovens

Interval Task
Daily Clean cavity; combi: run cleaning program (CleanJet etc.)
Weekly Check door gaskets; clean fan guard and air nozzles (rapid-cook)
Monthly Clean air filters; check fan motor; descale steam generator per water hardness
Semi-annual Calibrate temperature; inspect ignition/burners, elements, door hinges; combi: check water treatment

Commercial washers & dryers

Interval Task
Daily (dryers) Clean lint screens
Weekly Clean door gaskets/boots (washers); check for leaks; clear coin mechanisms
Monthly Clean lint chambers; inspect drain valves; check belts
Quarterly Inspect exhaust ducting (fire risk), gas burners, bearings, shocks, door locks
Yearly Full exhaust cleaning to the roof/wall cap; electrical and gas checks

What a PM visit from us includes (copy for site)

Want a plan for your location? Request a quote

Equipment down right now?

Same-day commercial service across the Charlotte area · Open 7 days · 7:00 AM – 10:00 PM