Delfield Error Codes

What Delfield fault codes and alarms mean, and what a technician checks for each one. Need it fixed? We repair Delfield equipment across the Charlotte area.

Danfoss display (6000XL, Specification Line)

CodeMeaningWhat to check
E-1Box temperature sensor open/shorted or control faulty
E-2Coil temperature sensor open/shorted or control defective
E-6Defective potentiometer in unit control
E-13Loose display-to-controller cable, or faulty display/control

ERC2 display (6000, ACR, Spec Line)

CodeMeaningWhat to check
Er 1 / Er 5Software or hardware failureReset; if persists, service.
Er 2Faulty display module cable
Er 3Temperature sensor open or shorted
Er 4Evaporator sensor open or shorted
Er 6Below low alarm setpoint
Er 7Above high alarm setpointCheck door, gasket, condenser.

ERC112 display (8100-EF, 18600)

CodeMeaningWhat to check
E01Defective air sensor
E02Faulty coil sensor
Lo / HiTemperature below / above setpoint
LEACooling continuously over 24 hResets when compressor cycles off.