Frymaster Error Codes
What Frymaster fault codes and alarms mean, and what a technician checks for each one. Need it fixed? We repair Frymaster equipment across the Charlotte area.
3000 controller
| Code | Meaning | What to check |
|---|---|---|
| E01 / E02 | REMOVE DISCARD right/left — setpoint differs from vat temp | |
| E03 | Temperature probe failure | |
| E04 | HI 2 BAD — high-limit reading out of range | |
| E05 | HOT HI 1 — high limit above 410°F | |
| E06 | HEATING FAILURE — controller, interface board, contactor, gas valve, open high limit | |
| E07 / E08 | MIB software error | |
| E09 | Pump not filling — dirty filter pad or pump | |
| E10 / E11 | Drain valve not open / not closed | |
| E12 / E13 | Return valve not open / not closed | |
| E14 | AIF board error | |
| E15 | MIB board error | |
| E16 / E17 | AIF / ATO probe out of range | |
| E19 | M3000 CAN TX full — lost communication | |
| E20 | Invalid code location (SD card removed) | |
| E21 | Change filter pad / procedure error | |
| E22 | Oil in pan error | |
| E23 | Clogged drain (gas) | |
| E24 | AIF OIB failed (gas) | |
| E25 / E26 | Recovery fault (recovery time exceeded) | |
| E27 / E28 | Low / high temp alarm |
CM III.5 computer
| Code | Meaning | What to check |
|---|---|---|
| PROB | Failed temperature probe or controller | |
| HOT | Frypot above 410°F — turn off | |
| HELP | Heating problem | |
| CALL TECH | Memory chip failure |