Call (980) 478-8030

Ice-O-Matic Error Codes

What Ice-O-Matic fault codes and alarms mean, and what a technician checks for each one. Need it fixed? We repair Ice-O-Matic equipment across the Charlotte area.

CIM / Elevation series (reset: hold Power + Clean 3 s)

CodeMeaningWhat to check
Error 1Max freeze (~1 hr) then short harvestCondenser fan motor, compressor, inlet valve overfilling, dirty condenser/evaporator, float switch.
Error 2Max harvest — ice did not drop within 7 minHot gas valve or curtain switch not opening, relay or gas valve stuck.
Error 3Hour-long freeze + 7-min harvestCompressor, water pump or condenser fan failure, board/relay, leaking harvest assist. Call IOM tech support.
Error 4Thermistor failureReplace thermistor.
Error 5Max fill — fill took 5+ minClogged filter, inlet valve, water supply off, float switch.
Error 6Max purge (2 min purge, off 10 min, retry)Water pump or purge valve, float switch.
Error 7Float switch did not open within 15 s of pump start (3 tries)Float switch, leaking inlet valve, high water pressure, connections.

Related service: Commercial Ice Machine Repair in Charlotte, NC

Equipment down right now?

Same-day commercial service across the Charlotte area · Open 7 days · 7:00 AM – 10:00 PM

📞 Call now