Manitowoc Error Codes
What Manitowoc fault codes and alarms mean, and what a technician checks for each one. Need it fixed? We repair Manitowoc equipment across the Charlotte area.
Indigo / Indigo NXT (E-codes)
| Code | Meaning | What to check |
|---|---|---|
| E01 | Long Freeze | Freeze cycle runs longer than allowed. Check condenser airflow/cleanliness, water flow, scale, ice thickness probe, refrigeration. |
| E02 | Long Harvest | Harvest cycle longer than allowed. Check hot gas valve, harvest assist, water curtain, scale on evaporator. |
| E03 | Power Loss | Input power interrupted or lost. |
| E04 | Hi Cnd Temp / Wtr Cnd Fault | Condenser too hot (air- or water-cooled). Clean condenser, check fan, water regulating valve. |
| E05 | HPC Fault | High-pressure control opened. |
| E07 | Starving TXV | Evaporator starved of refrigerant (TXV or low charge). |
| E08 | TXV Fault | Fault in single- or dual-circuit evaporator TXV. |
| E09 | Flood Evap 1 | Evaporator flooding (single circuit, single evaporator). |
| E10 | Flood Evap 2 | Evaporator flooding (dual circuit, single evaporator). |
| E11 | Refrig Fault | Refrigeration system fault (air/water-cooled). |
| E12 | Curtain Fault | Curtain switch open for over 24 hours. |
| E15 | Low Liq Temp | Low ambient: liquid line below 60°F for over 1 minute during freeze. |
| E16 | Rmt Cnd Temp | Remote condenser: liquid line below 40°F or above 140°F for over 1 minute during freeze. |
| E19 | ITP Fault | Ice thickness probe fault. |
| E20 | WTR Fault | Water system fault. |
| E21 | T1 Fault | T1 temperature sensor problem. |
| E22 | T2 Fault | T2 temperature sensor problem. |
| E23 | T3 Fault | T3 temperature sensor problem. |
| E24 | T4 Fault | T4 temperature sensor problem. |
| E25 | Bin Prb Fault (low) | Bin level probe, low sensor. |
| E26 | Bin Prb Fault (medium) | Bin level probe, medium sensor. |
| E27 | Bin Prb Fault (high) | Bin level probe, high sensor. |
| E28 | AuCS | AuCS board missing or not connected. |
| E29 | USB COMM | Defective or missing USB drive. |
| E30 | USB DNLD | Download error from defective USB drive. |
| E31 | Safe Mode | Machine running in safe mode. |
| E32 | RS485 COMM | No communication between control board and RS485 device. |
| E33 | KEYBOARD | Keyboard faulty or unplugged from control board. |
| E34 | DISPLAY | Display fault (verify against service manual). |
Related service: Commercial Ice Machine Repair in Charlotte, NC